Capatect MW-Brandriegel 035 152

Universal fire barrier for use in flame-retardant Exterior Thermal Insulation Composite Systems based on EPS insulation boards

LV Texte

Field of Application

Non-combustible facade insulation board for use as fire barrier in ETICS based on EPS insulation boards. To be fixed with adhesive mortar and anchors. Not for use on timber frame.

Material Properties

Application type: WAP-zg according to DIN 4108-10
No initial mortar priming required
White coated front side for a better adhesion of the reinforcing layer 
Edges: blunt
Officially quality-monitored by FIW Munich
Occupational health classification (Germany): free according to GefStoffV, ChemVerbotsV and EC Directive 97/69 (Note Q)

Colours

Insulation: Brownish yellow
Coating: White coating on front side. White with uncoated stripes on back side towards the adhesive mortar side.

Storage

Dry, protected from moisture, do not expose to weather without protection.

Heat conductivity

λB = 0.035 W/(m·K) rated value according to DIN 4108-4
λD = 0.034 W/(m·K) nominal value according to DIN EN 12667 or DIN EN 12939

Resistance-count for diffusion µ (H2O)

µ = 1 according to DIN EN 12086

Compressive stress (compression: 10%)

≥ 10 kPa according to DIN EN 826

Temperature resistance

up to 250 °C for a short time

Raw density

ρ: approx. 105 kg/m3 according to DIN EN 1602

Fire behaviour

Class A1 according to DIN EN 13501-1 (non-combustible)

Melting point

> 1000 °C according to DIN 4102-17

Adhesive tensile (pull-off) strength at right angle to the panel plane

≥ 5 kPa according to DIN EN 1607

Product No.

Thickness  [ mm ]Prod.-N°[ m2 ] per hood-shrunk bundle
100152/10



0.96
120152/12
140152/14
160152/16
180152/18
200152/20
220152/22


0.48
240152/24
260152/26
280152/28
300152/30

Suitable Substrates

Mineral substrates, solid old renders, stable old paint or coatings, as well as other stable, even substrates and in accordance with the information in the general Building authority approval / general type approvals for the ETICS.

Substrate Preparation

Pre-treat substrates in accordance with the processing instructions for the adhesive mortar.

Consumption

1.0 m2/m2; plus offcuts

Application Conditions

During application and the curing phase, the temperature of the environment and substrate must not fall below +5°C or rise above 30°C. In the event of unfavourable weather conditions, take appropriate measures to protect the treated façade surfaces.

Bonding of Insulation Boards

- Lay insulation boards and butt joints tightly
- Butt joints must remain free of adhesive
- Avoid height offset at the board joints
- Damaged insulation boards must not be installed

Manual bonding of the insulation board:
Bonding is carried out using mineral adhesive mortar suitable for the system. The adhesive must be applied to the back of the board, which is marked with strips, using the toothed bed method so that the entire surface is bonded to the substrate. For full-surface adhesive application to the wall, comb through the adhesive with a notched trowel (the width and depth of the teeth depends on the condition of the substrate) immediately before attaching the insulation board. The insulation boards must be pressed, floated in and pressed onto the substrate immediately, after 10 minutes at the latest, with the side to which the adhesive has been applied.

Base fire protection zone:
After sufficient curing time of the adhesive, the Capatect MW-Brandriegel 152 must be additionally fixed with 3 anchors per strip element. Building authority approved anchors with steel expansion element such as Capatect Universaldübel 053 or Capatect Schlagdübel 061 must be used for fixing. Edge and intermediate distances of the anchors: at least 10 cm upwards and downwards, maximum 20 cm to the side edges of a fire break strip element and maximum 40 cm to the neighbouring anchor.

Room fire protection zone:
In the "room fire" protection zone, the Capatect MW-Brandriegel 152 must be fixed with at least 2 anchors per strip element. Property-specific structural analyses may result in a higher number of anchors.

Special Risks (Hazard Note) / Safety Advice (Status as at Date of Publication)

If dust occurs, wear protective clothing (dust-proof) and a dust mask P1. Wear safety glasses when carrying out mechanical processing (sawing, drilling, grinding, milling) and when working overhead.

Disposal

Waste must be avoided by careful cutting and re-use. Nevertheless resulting low material residues to be disposed as per EWC 170604 (insulation material).

Approval

Z-33.43-132
Z-33.49-1071
Z-33.41-130
Z-33.42-131
Z-33.46-1091

Customer Service Centre

Tel.: +49 6154 71-71710
Fax: +49 6154 71-71711
e-mail: kundenservicecenter@caparol.de

International Distribution: Please see www.caparol.com

Technical information

Technical information