Field of Application
Special primer with good coverage and slip resistance as an adhesion-promoting pre-coat for subsequent synthetic resin, silicone resin, silicate and mineral plasters as well as coloured stone plaster coatings in Capatect façade systems.
For well-covering, slip-resistant base coats on stable, mineral interior surfaces and plasterboard (GK boards).
PutzGrund 610 can also be used as a textured and coloured base coat, for the so-called ‘brush stroke’ effect, for glaze techniques with Arte-Lasur and Deco-Lasur, and as a base coat for Capadecor VarioPutz.
Material Properties
- Facilitates the application and structuring of subsequent coatings for higher surface coverage
- Reduces the water absorption of the substrate
- High adhesive strength and extended open time for subsequent coatings
- Prevents the reinforced from showing through under fine-grained finishing render
- Burn-off barrier for mineral and (dispersion) silicate finishing renders
- Water-dilutable
- Free of solvents and preservatives
Material Base / Vehicle
Modified, remineralising plastic dispersion according to DIN 55945Packaging/Package Size
Standard goods: 8 kg, 16 kg, 25 kg
ColorExpress: 16 kg
Colours
White.
Can be tinted with CaparolColor and AmphiColor Abtönfarben colours or mechanically using the ColorExpress system. Tinting means that the preservative-free property is no longer guaranteed.
When using Histolith Volltonfarben (solid colours, max. 10%), the preservative-free property remains guaranteed. When tinting using a Caparol UV-C tinting system, the end product remains preservative-free.
Before processing, check the material for colour accuracy and quality. Complaints regarding deviations from the delivery specifications cannot be accepted after processing. Please refer to the VDPM's "Leitfaden zu Prüfpflichten bei Anlieferung von Tönware im Rahmen der Untersuchungs- und Rügepflicht (§ 377 HGB)" (‘Guidelines on inspection obligations for the delivery of coloured goods within the scope of the obligation to inspect and give notice of defects, § 377 of the German Commercial Code HGB)’.
Only process material from the same batch on contiguous surfaces or mix material from different batches beforehand.
For intense and poorly covering colours, we recommend a base coat in the appropriate Caparol primer system colour, or alternatively a pastel, white-based base coat comparable to the desired colour or a pigmented primer.
An additional top coat may be necessary.
Gloss Level
Reflectometer value:
Class G3 (matt) according to DIN EN 1062-1
Measuring angle 85°, requirement ≤ 10
Storage
Store in a cool, frost-free place and avoid large temperature fluctuations. Protect from direct sunlight. Keep opened containers tightly closed.
Can be stored for at least 24 months in the original sealed packaging.
Technical Data
- Fire behaviour ‘non-combustible’ or ‘flame-retardant’ depending on the structure of the respective Capatect façade system
Maximum particle (grit) size
Class S2 (medium) according to DIN EN 1062-1
S < 300 µm according to ISO 787
Density
ρ ≈ 1.6 g/cm3Diffusion-equivalent air layer thickness sdH2O
Category V1 (high) according to DIN EN 1062-1
sd < 0.14 m according to DIN EN ISO 7783-2
Supplementary Product
PutzGrund 610 SPRINTERNote
Please note the general building authority approval/general type approval and the technical information for the systems/products involved.The values provided represents average values, which may vary slightly from delivery to delivery due to the use of natural raw materials.
The information refers to white goods or standard goods. Deviations are possible due to colour tinting.
Suitability according to Technical Information No. 606 Definition of Application Areas
| Interior 1 | Interior 2 | Interior 3 | Exterior 1 | Exterior 2 |
| + | + | + | + | + |
| (–) inapplicable / (○) of limited suitability / (+) suitable | ||||
Suitable Substrates
- Mineral substrates, e.g. plasters from CS II according to DIN EN 998-1 (compressive strength min. 1.5 N/mm2) or from PII according to DIN 18550
- Organically bound base coats and fillers
- Plasterboard (GK boards) indoors
- For Capadecor VarioPutz: firmly adhering woodchip or glass fibre, as well as light to medium textured renders indoors
- Can be used in ETICS and VHF, in solid construction and renovation
The substrate must be load-bearing, free of contamination, separating substances and dry. Observe VOB, Part C, DIN 18363, Section 3. The substrate inspection is carried out in accordance with technical rules nos. 20 and 20.1 of the Bundesausschuss Farbe und Sachwertschutz e.V. (BFS, Federal Committee for Paint and Property Protection).
Substrate Preparation
The substrate inspection is carried out in accordance with technical rules nos. 20 and 20.1 of the Bundesausschuss Farbe und Sachwertschutz e.V. (BFS, Federal Committee for Paint and Property Protection). Identify the cause of cracks in substrates and repair them appropriately, depending on the type and extent of the cracks.Please refer to Caparol Technical Information No. 650 "Untergründe und deren Vorbehandlung" (‘Substrates and their pre-treatment’).
The following information is provided as examples and is not exhaustive. The coating is applied after any necessary substrate preparation.
Protective measures:
Carefully cover glass, ceramics, clinker, natural stone, lacquered, glazed, anodised and other surfaces to be protected. Remove splashes immediately with water.
Cleaning the substrates:
Clean dirty areas and remove any loose layers using a suitable method. Observe legal requirements. Allow sufficient drying time after treatment with water.
Possible methods (not exhaustive):
- Dry cleaning: sweeping, brushing.
- Pressure washing: max. temperature 60°C, max. pressure 60 bar.
- Mechanical cleaning: pickling, grinding, scraping, local dismantling, etc.
The waiting time before new renders can be reworked depends, among other things, on weather conditions and the layer thickness. It is longer at low temperatures and high humidity. The information is based on 20 °C and 65 % relative humidity and is provided for guidance only.
- New mineral plasters: at least 1 day per mm of base coat thickness, but at least 5 days. Longer waiting times reduce the risk of lime efflorescence.
- New paste-like (organic) plasters: after complete drying, at least 2-3 days.
Old mineral renders, concrete, mineral coatings:
Slightly absorbent, smooth: Prime coat with CapaGrund Universal.
Coarse, porous, absorbent, slightly sandy: Prime coat with OptiSilan TiefGrund or CapaSol RapidGrund.
Heavily sandy, chalky: Prime coat with OptiSilan Tiefgrund or Dupa-Putzfestiger.
Old, pasty, matt coatings:
Highly absorbent, chalky, sandy: Base coat with OptiSilan TiefGrund or Dupa Putzfestiger.
Plasterboard (GK boards):
Sand down any filler ridges. Prime sanded plaster filler areas and plasterboard with OptiSilan TiefGrund, CapaSol RapidGrund or Sylitol RapidGrund 111.
For more absorbent surfaces, apply a base coat of OptiSilan TiefGrund. For boards containing water-soluble, discolouring substances, apply a base coat of Caparol-Filtergrund grob. Observe BFS technical rule no. 12, part 2.
Note Q2/Q3 filling / thin plaster layers < 0.5 mm:
When using gypsum-based, hydraulically setting fillers in quality grade Q2/Q3, a transparent, water-based primer is recommended. Reference is made to information sheet no. 2 -9/2020 ‘Adhesion problems with coatings on filled plaster (board) panels’ from the Bundesverband Farbe Gestaltung Bautenschutz (Federal Association for Paint, Design and Building Protection) and the Bundesausschuss Farbe und Sachwertschutz (BFS, Federal Committee for Paint and Property Protection). As an alternative to gypsum-based Q3 filling, filling with paste-like fillers has proven effective.
Method of Application
To avoid lapping, coat wet-on-wet in one go.
Application with brush/roller
Stir the material well. Dilute with max. 10% water to achieve the desired consistency.
Airless spraying
Stir the material well. Dilute with max. 10% water to achieve the desired consistency.
Machine technology: Powerful airless devices, e.g. Airless Heavy, Duty/Heavy, Coat/Textspray Nozzle: 0.027"– 0.031"
Spraying pressure: 100–120 bar
Light rolling of the still wet coating or cross-brushing with a brush is recommended. Fog-free
application is not guaranteed. Spraying is only permitted in compliance with environmental and
occupational safety regulations.
Paste-like finishing render (e.g. Capatect ThermoSan Fassadenputz NQG, AmphiSilan-, Muresko-Fassadenputze, Fassadenputz FEIN) | Mineral finishing render (e.g. Capatect Mineral-Leichtputz, Mineralputz, Modellier- and Spachtelputz 134, Feinspachtel 195) | Silicate finishing render (e.g. Capatect Sylitol Fassadenputz) | |
Mineral base coat | 1, 3 | 1, 2, 3 | 1, 2, 3 |
Paste-like base coat | 1, 3 | / | 1, 3 |
Plinth products | 1 | 1, 3 | 1 |
Capatect Buntstein-Sockelputz 691 / | PutzGrund 610 required as a base or intermediate coat, in a colour to match the final coat. | ||
1 | PutzGrund 610 recommended
| ||
2 | PutzGrund 610 recommended in very dry or warm weather as a burn barrier. | ||
3 | PutzGrund 610 recommended on weathered base coats, e.g. after prolonged storage. | ||
Consumption
- Approx. 250-350 ml/m2 per coat on smooth surfaces.
Use more on rough surfaces. Determine exact consumption by applying a test coat.
Application Conditions
During the application and in the drying phase, the ambient and substrate temperatures must not be below +5 °C and above +30 °C.
Do not apply in direct sunlight, strong wind, fog or high humidity. Please refer to the leaflet "Verputzen, Wärmedämmen, Spachteln, Beschichten bei hohen und tiefen Temperaturen" (Rendering, Thermal Insulation, Filling, Coating at High and Low Temperatures) from the Bundesverband Ausbau und Fassade (Federal Association for Finishing and Facades).
In unfavourable weather conditions, take suitable measures to protect the facade surfaces being treated.
Drying/Drying Time
The waiting time before recoating depends, among other things, on weather conditions and the thickness of the coat. It is longer at low temperatures and high humidity.
The information is based on 20 °C and 65 % relative humidity and is intended as a guide.
- Surface dry after approx. 3 hours
- Can be painted over after approx. 12 hours
- Completely dry and resistant to stress after approx. 3 days
Tool Cleaning
Rinse with water immediately after use in accordance with legal regulations.
Note
Protect horizontal surfaces constructively (e.g. by sheet metal).Special Risks (Hazard Note) / Safety Advice (Status as at Date of Publication)
Safety data sheet available on request. For professional/industrial applications.. Due to its potassium silicate content, the reaction of silicate based coatings is highly alkaline. Hence protect skin and eyes from paint.Disposal: Materials and all related packaging must be disposed of in a safe way in accordance with the full requirements of the local, regional, national and international authorities. Washing water must not be discharged into the sewage system or the environment.
GISCODE: BSW40.
EU limit value for the VOC content of this product (category A/c): 40 g/l . This product contains max. 1 g/l VOC.
Declaration of ingredients according to VdL directive 01 (Germany): polyacrylic resin, alkali water glass, calcium carbonate, silicates, water, additives.
Further Details
| Approvals | |
| Z-33.41-130 Z-33.41-1706 Z-33.42-1739 Z-33.43-132 Z-33.43-606 Z-33.43-1666 Z-33.43-1667 Z-33.43-1707 Z-33.43-1746 Z-33.44-133 Z-33.47-859 Z-33.1-171 | ETA-12/0383 ETA-07/0184 ETA-08/0304 ETA-10/0436 ETA-11/0300 |
Technical Assistance
This document cannot cover all substrates encountered in practice and their technical treatment. If substrates are to be treated that are not listed in this technical information, it is necessary to consult us or our sales representatives. We will be happy to provide you with detailed and project-specific advice.Customer Service Centre
Tel.: +49 6154 71-71710Fax: +49 6154 71-71711
e-mail: kundenservicecenter@caparol.de
International Distribution: Please see www.caparol.com
Technical information
- Technical Information No. 659 - PutzGrund 610
- Technical Information No. 611
- Technical Information No. 606 - "Definition of Application Areas"
Sustainability data sheet
Material safety data sheet
Technical information
- Technical Information No. 659 - PutzGrund 610
- Technical Information No. 611
- Technical Information No. 606 - "Definition of Application Areas"