Field of Application
Special interior paint for quick and environmentally compatible renovation of nicotine stained walls an ceilings. IsoDeck has a shut-off effect against nicotine discolouration, that would lead to visible stains when common water-dilutable interior paint is used.IsoDeck is solvent-free and fast-drying, hence most suitable for living rooms, offices, restaurants, hotels etc., since no long waiting times must be respected and no unpleasant odour occurs.
Ideal problem solvers: If used in combination with primer Caparol AquaSperrgrund, even problematic jobs (e.g. renovation of surfaces stained with nicotine and/or dried water, soot or fat/grease), can be handled in an environmentally compatible way.
Material Properties
- Solvent-free, unplasticized.
- Water-dilutable, environmentally compatible, low odour.
- Good shut-off properties.
- Diffusion-capable.
- sd-value < 0.1 m
Material Base / Vehicle
Synthetic resin dispersion/emulsion according to German standard DIN 55945.Packaging/Package Size
- Standard Product: 12.5 l
Colours
White.IsoDeck can be tinted to a max. of 10 % with CaparolColor or AmphiColor® (AVA) colourants.
If more than one bucket is manually tinted, all product must be thoroughly mixed before use to avoid colour differences.
Gloss Level
G4 - Dull mattStorage
Keep in a cool, but frost free place.Technical Data
Characteristics according to DIN EN 13 300:
Tinting may cause variations.
Wet abrasion
R-class 2Contrast ratio
H10-class 1, with 8 m2/lMaximum particle (grit) size
S1 Fine (up to 100 µm)Density
Approx. 1.5 g/cm3Diffusion-equivalent air layer thickness sdH2O
<0,1 m sd according to DIN EN 1062Suitability according to Technical Information No. 606 Definition of Application Areas
Interior 1 | Interior 2 | Interior 3 | Exterior 1 | Exterior 2 |
+ | + | – | – | – |
(–) inapplicable / (○) of limited suitability / (+) suitable |
Suitable Substrates
The substrate must be sound/stable, dry, clean, and free from all substances that may prevent good adhesion. In Germany: Follow VOB, part C, DIN 18363, section 3.Wash off nicotine, soot and fat/grease stains with tap water, adding a fat-dissolving household cleaning agent, and allow to dry well. Clean dried-up water stains by dry brushing-off.
Substrate Preparation
Renders according to DIN EN 998-1 class CS II - CS IV / compressive strength min. 2 N/mm2: Solid, normally absorbent and even renders can be coated without primer coat. Prime slightly sanding, absorbent renders with OptiSilan TiefGrund, CapaSol RapidGrund or Sylitol RapidGrund 111. Prime more sanding renders with OptiSilan TiefGrund.
Gypsum plasters according to DIN EN 13279-1 / compressive strength min. 2 N/mm2: Sand and remove dust from gypsum plasters with sintered skin, prime with OptiSilan TiefGrund, CapaSol RapidGrund or Sylitol RapidGrund 111.
Gypsum boards/gypsum planks: Prime absorbent boards with OptiSilan TiefGrund (for planking, see also plasterboard).
Gypsum boards (plasterboard): Sand off filler burrs. Prime sanded gypsum filler areas and the gypsum boards with OptiSilan TiefGrund, CapaSol RapidGrund or Sylitol RapidGrund 111. In case of stronger absorption, prime with OptiSilan TiefGrund. For boards with water-soluble, discolouring ingredients, prime with Caparol AquaSperrgrund fein (observe Technical information No. 845) . Observe BFS Data Sheet No. 12, Part 2.
Concrete: Remove any release agent residues and chalking, sanding substances. Prime with OptiSilan TiefGrund, CapaSol RapidGrund or Sylitol RapidGrund 111.
Load-bearing coatings: Recoat matt, slightly absorbent coatings directly. Roughen glossy surfaces and paint coatings.
Non-bearing coatings: Remove non-stable varnish and dispersion paints or synthetic resin plaster coatings. Prime coarsely porous, sanding or absorbent surfaces with OptiSilan TiefGrund. Remove non-bearing mineral paint coatings mechanically and remove dust from the surfaces. Apply one priming coat of OptiSilan TiefGrund.
Glue-Bound Distemper (Limewater Colour/Paint): Wash off thoroughly. Alternatively, remove mechanically, rinse and prime with OptiSilan TiefGrund.
Woodchip, relief or embossed wallpapers made of paper and sample wallpapers: Coat without pre-treatment. For relief and embossed wallpapers made of paper as well as sample wallpapers, apply a trial coat. Foamed wallpapers may cause intermediate reactions (stickiness, odour) when coated.
Mould-infested surfaces: Remove mould by wet cleaning. Wash surfaces with Capatox and allow to dry thoroughly. Observe the legal and official regulations (e.g. the Biological Substances Ordinance and the Ordinance on Hazardous Substances). Increased protection against renewed infestation can be achieved with the products Malerit-W, Indeko-W and Fungitex-W.
Surfaces with nicotine, water, soot or grease stains: Wash off nicotine stains as well as soot or grease stains with water, adding a grease-dissolving cleaning agent, and allow to dry thoroughly. Clean dried water stains by brushing dry. Apply a barrier priming coat of Caparol AquaSperrgrund fein (see Technical Information No. 384) or Caparol-Filtergrund grob (see Technical Information No. 845).
Wood and wood-based materials: Apply one priming coat of Capacryl Holz-Isogrund (observe Technical Information No. 961). On boards factory-coated with melamine resin, apply one priming coat of Capacryl-Haftprimer (observe Technical Information No. 980). The joint areas/panel joints are not to be finished crack-free. Here, for higher visual requirements, a decoupling layer with thin gypsum boards with appropriate filling is recommended.
Chips, joints and defects: Fill the recess with Füllspachtel P.
Note Q2/Q3 Filling / thin gypsum layers < 0.5 mm: When using gypsum-containing, hydraulically setting levelling compounds in quality level Q2/Q3, a transparent, water-based primer is recommended. For this, we refer to the Maler&Lackierer Merkblatt No. 2 -9/2020 "Adhesion problems of coatings on filled gypsum (cardboard) boards" of the Bundesverband Farbe, Gestaltung, Bautenschutz and the Bundesausschuss Farbe und Sachwertschutz. As an alternative to gypsum-based Q3 filling, filling with pasty filling compounds has proven successful.
Method of Application
Apply with paint brush, paint roller or suitable paint spraying equipment.Airless application:
Delution | max. 5% with waterr |
Airless device | |
Spray pressure | 180 - 200 bar |
Spray angle | 40° - 50° |
Nozzle size in Inch | 0.019 - 0.025" |
Plug-in pistol filter in MW | ca. 0.31 mm |
Internally fed roller systems | |
Spray pressure | 80 - 120 bar |
Plug-in pistol filter in MW | ca. 0.31 mm |
Clean tools with water after use.
Please note: Stir and sieve the paint before spraying. If necessary, a Metex cage can also be used. It is always advisable to lightly roll the still wet coating with a fine inner roller (e.g. Rotanyl 18). This achieves a uniform surface appearance. Clean the appliance with water immediately after use. If work is interrupted, leave the appliance in the paint, cover the container with foil, for example, and keep the gun and nozzle under water. For covering measures, see general instructions. Remove splashes immediately with clean water.
Surface Coating System
Surfaces with normal nicotine contamination:A rich, even coat of IsoDeck, diluted with max. 5 % water. On high-contrast surfaces, first apply a primer coat of IsoDeck, diluted with 5-10 % water. On coarsely porous, sandy and highly absorbent substrates, apply a primer coat of CapaSol RapidGrund or CapaSol Konzentrat. On differently absorbent substrates, apply a priming coat of Caparol AquaSperrgrund or HaftGrund EG.
Surfaces highly stained with nicotine and/or water, soot and fat/grease:
One priming coat with Caparol AquaSperrgrund, undiluted. After the primer coat has dried thoroughly (at least 12 hours), apply one or two coats of IsoDeck, diluted with max. 5 % water.
Consumption
Caparol AquaSperrgrund approx. 110 ml/m2 and IsoDeck approx. 125 ml/m2 per coat on smooth surfaces. On roughly textured substrates correspondingly more.Application Conditions
Lower Temperature Limit for Application and Drying:
+5 °C for product, substrate and ambient air.
Drying/Drying Time
At +20 °C and 65 % relative humidity Caparol AquaSperrgrund is recoatable after approx. 12 hours and IsoDeck after 4–6 hours. Lower temperatures and higher humidity extend the drying time.Note
For extremely contaminated or stained surfaces or rooms that must be renovated and completed within one day, we recommend the highly covering and low odour paint Dupa-inn for quick renovation. Follow Technical Information No. 385.Stir well and sieve the paint for airless application.
Touching up surfaces is depending on many parameters and may be visible after drying.
(In Germany: See BFS Data Sheet No. 25)
Please Note (Status as at Date of Publication)
Harmful to aquatic life with long lasting effects. Avoid release to the environment. Dispose of contents/ container to an approved waste disposal plant. Contains 1,2-benzisothiazol-3(2H)-one, reaction mass of 5-chloro-2-methyl-2H-isothiazol-3-one and 2-methyl-2H-isothiazol-3-one (3:1). May produce an allergic reaction. Warning! Hazardous respirable droplets may be formed when sprayed. Do not breathe spray or mist. For commercial/industrial applications.0800/1895000 (free of charge from the German landline network).
Disposal
Materials and all related packaging must be disposed of in a safe way in accordance with the full requirements of the local authorities. Particular attention should be made to removing wastage from site in compliance with standard construction site procedures.In Germany: Only completely empty containers should be handed in for recycling. Dispose containers with residues of liquid product via waste collection point accepting old paints and enamels. Dispose dried/hardened product residues as construction site/demolition/municipal or domestic waste.
EU limit value for the VOC content
of this product (category A/a): 30 g/l (2010). This product contains < 1 g/l VOC.Giscode
BSW20Substances of Content - Declaration
Polyvinylacetate resin, silicates, titanium dioxide, calcium carbonate, mineral pigments / fillers, water, additives, preservative.Technical Assistance
All substrates encountered in practice and their technical processing cannot be dealt with in this publication. If substrates are to be treated that are not listed in this technical information, it is necessary to consult us or our sales representatives. We will provide you with detailed and object-related advice.Customer Service Centre
Tel.: +49 6154 71-71710Fax: +49 6154 71-71711
e-mail: kundenservicecenter@caparol.de
International Distribution: Please see www.caparol.com